Gardnerella Vaginalis Nucleic Acid
Dzina la chinthu
HWTS-UR042-Gardnerella Vaginalis Nucleic Acid Detection Kit (Fluorescence PCR)
Epidemiology
Choyambitsa chachikulu cha vaginitis mwa akazi ndi bacterial vaginosis, ndipo bakiteriya wofunikira kwambiri wa bacterial vaginosis ndi Gardnerella vaginalis. Gardnerella vaginalis (GV) ndi tizilombo toyambitsa matenda tomwe sitimayambitsa matenda tikakhala tochepa. Komabe, pamene mabakiteriya akuluakulu a m'mimba a Lactobacilli achepa kapena kuchotsedwa, zomwe zimapangitsa kuti pakhale kusalingana m'malo obisika a m'mimba, Gardnerella vaginalis imachulukana kwambiri, zomwe zimapangitsa kuti pakhale bacterial vaginosis. Nthawi yomweyo, tizilombo tina (monga Candida, Neisseria gonorrhoeae, Chlamydia trachomatis, ndi zina zotero) timakhala ndi mwayi wolowa m'thupi la munthu, zomwe zimayambitsa vaginitis yosakanikirana ndi cervicitis. Ngati vaginitis ndi cervicitis sizipezeka ndi kuchiritsidwa mwachangu komanso moyenera, pakhoza kukhala matenda opatsirana kudzera m'matenda obereketsa, zomwe zimapangitsa kuti pakhale matenda opatsirana m'mimba monga endometritis, salpingitis, tubo-ovarian abscess (TOA), ndi pelvic peritonitis, zomwe zingayambitse mavuto aakulu monga kusabereka, mimba yotuluka m'mimba komanso zotsatira zoyipa za mimba.
Magawo aukadaulo
| Malo Osungirako | -18℃ |
| Nthawi yokhalitsa | Miyezi 12 |
| Mtundu wa Chitsanzo | swab ya mkodzo ya amuna, swab ya m'chiberekero ya akazi, swab ya m'chiberekero ya akazi |
| Ct | ≤38 |
| CV | <5.0% |
| LoD | Makope 400/mL |
| Zida Zogwiritsidwa Ntchito | Ingagwiritsidwe ntchito pa reagent yozindikira mtundu woyamba:Machitidwe a Biosystems Ogwiritsidwa Ntchito 7500 Real-Time PCR, QuantStudio®Machitidwe 5 a PCR a Nthawi Yeniyeni, Makina a PCR a SLAN-96P Real-Time (Hongshi Medical Technology Co., Ltd.), Makina Ozindikira a PCR a LineGene 9600 Plus Real-Time (FQD-96A, ukadaulo wa Hangzhou Bioer), MA-6000 Real-Time Quantitative Thermal Cycler (Suzhou Molarray Co., Ltd.), Dongosolo la BioRad CFX96 Real-Time PCR, BioRad CFX Opus 96 Real-Time PCR System. Yogwiritsidwa ntchito pa reagent yozindikira mtundu wachiwiri: EudemonTMAIO800 (HWTS-EQ007) yopangidwa ndi Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. |
Kuyenda kwa Ntchito
Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017) (yomwe ingagwiritsidwe ntchito ndi Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)), ndi Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-8) (yomwe ingagwiritsidwe ntchito ndi EudemonTM AIO800 (HWTS-EQ007)) yopangidwa ndi Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.
Kuchuluka kwa chitsanzo chochotsedwa ndi 200μL ndipo kuchuluka kwa elution komwe kumalimbikitsidwa ndi 150μL.