Xinjiang Hemorrhagic Fever Virus
Dzina la malonda
HWTS-FE007B/C Xinjiang Hemorrhagic Fever Virus Nucleic Acid Detection Kit (Fluorescence PCR)
Epidemiology
Xinjiang hemorrhagic fever virus idasiyanitsidwa koyamba ndi magazi a odwala omwe ali ndi malungo a hemorrhagic ku Tarim Basin, Xinjiang, China ndi nkhupakupa zolimba zomwe zidagwidwa kwanuko, ndipo zidali ndi dzina. chipatala mawonetseredwe monga malungo, mutu, magazi, hypotensive mantha, etc. Zofunika pathological kusintha kwa matendawa ndi zokhudza zonse capillary dilatation, kuchulukana, kuchuluka permeability ndi fragility, chifukwa mu osiyanasiyana kuchulukana ndi kukha magazi pakhungu ndi mucous zimagwira ntchito zosiyanasiyana komanso zimakhala za ziwalo zosiyanasiyana thupi lonse, ndi alibe ndi monga, necrosis, livertual gland, adrenal gland, etc. edema ngati odzola mu retroperitoneum.
Channel
FAM | Xinjiang Hemorrhagic Fever Virus |
Mtengo ROX | Ulamuliro Wamkati |
Technical Parameters
Kusungirako | ≤-18 ℃ |
Alumali moyo | 9 miyezi |
Mtundu wa Chitsanzo | seramu yatsopano |
Tt | ≤38 |
CV | <5.0% |
LoD | 1000 Makopi / ml |
Mwatsatanetsatane | Palibe kupatsirananso ndi zitsanzo zina zopumira monga Influenza A, Influenza B, Legionella pneumophila, Rickettsia Q fever, Chlamydia pneumoniae, Adenovirus, Respiratory Syncytial Virus, Parainfluenza 1, 2, 3, Coxsackie virus, Echo virus, Metapnevirus A1/B2 syncytial virus A/B, Coronavirus 229E/NL63/HKU1/OC43, Rhinovirus A/B/C, Boca virus 1/2/3/4, Chlamydia trachomatis, adenovirus, etc. ndi DNA ya anthu genomic. |
Zida Zogwiritsira Ntchito | Applied Biosystems 7500 Real-Time PCR Systems, Applied Biosystems 7500 Fast Real-Time PCR Systems Zithunzi za QuantStudio®5 Real-Time PCR Systems SLAN-96P Real-Time PCR Systems LightCycler®480 Real-Time PCR system LineGene 9600 Plus Real-Time PCR Detection Systems MA-6000 Real-Time Quantitative Thermal Cycler BioRad CFX96 Real-Time PCR System BioRad CFX Opus 96 Real-Time PCR System |
Kuyenda Ntchito
Analimbikitsa m'zigawo reagent: Macro & yaying'ono-Test Viral DNA/RNA Kit (HWTS-3017) (yomwe ingagwiritsidwe ntchito ndi Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-EQ011)) ndi Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Voliyumu yotulutsidwa ndi 200µL, ndipo voliyumu yovomerezeka ndi 80µL.
Regent yovomerezeka yochotsa: QIAamp Viral RNA Mini Kit (52904) yolembedwa ndi QIAGEN ndi Nucleic Acid Extraction kapena Purification Reagent (YDP315-R). The m'zigawo ayenera kuchitidwa mosamalitsa malinga ndi malangizo ntchito. Voliyumu yotulutsidwa ndi 140µL, ndipo voliyumu yovomerezeka ndi 60µL.