Kiti Yodziwira Ureaplasma Urealyticum Nucleic Acid (Fluorescence PCR)
Dzina la Chinthu
Kiti Yodziwira Ureaplasma Urealyticum Nucleic Acid (Fluorescence PCR)
Epidemiology
Ureaplasma urealyticum (UU) ndi kachilombo kakang'ono kwambiri ka prokaryotic komwe kamakhala paokha pakati pa mabakiteriya ndi mavairasi, komanso ndi kachilombo kakang'ono kwambiri komwe kamakhala ndi matenda opatsirana m'mimba ndi m'mitsempha ya mkodzo. Kwa amuna, kangayambitse prostatitis, urethritis, pyelonephritis, ndi zina zotero. Kwa akazi, kamayambitsa kutupa m'njira yoberekera monga vaginitis, cervicitis, ndi matenda otupa m'chiuno. Ndi chimodzi mwa tizilombo toyambitsa matenda zomwe zimayambitsa kusabereka ndi kuchotsa mimba. Ureaplasma urealyticum imagawidwa m'magulu 14, omwe amagawidwa m'magulu awiri malinga ndi makhalidwe a maselo: gulu lachilengedwe Ⅰ (Kukwera) ndi gulu lachilengedwe Ⅱ (Uu). Gulu lachilengedwe I limaphatikizapo ma serotypes 4 okhala ndi majini ang'onoang'ono (1, 3, 6, ndi 14); gulu lachilengedwe II limaphatikizapo ma serotypes 10 otsala okhala ndi majini akuluakulu.
Njira
| FAM | Asidi ya nucleic ya UU |
| VIC(HEX) | Kulamulira Kwamkati |
Magawo aukadaulo
| Malo Osungirako | Madzi:≤-18℃ Mumdima |
| Nthawi yokhalitsa | Miyezi 12 |
| Mtundu wa Chitsanzo | mkodzo wa mwamuna, swabu ya mkodzo wa mwamuna, swabu ya m'chiberekero ya mkazi |
| Ct | ≤38 |
| CV | ≤5.0% |
| LoD | Makopi 50/zochita |
| Kufotokozera Mwapadera | Palibe njira yolumikizirana ndi matenda ena opatsirana pogonana omwe sapezeka mu kit, monga Chlamydia trachomatis, Neisseria gonorrhoeae, Mycoplasma genitalium, herpes simplex virus type 1, ndi herpes simplex virus type. |
| Zida Zogwiritsidwa Ntchito | Ikhoza kufanana ndi zida zazikulu za PCR za fluorescent zomwe zili pamsika.Machitidwe a Biosystems 7500 a Real-Time PCRMakina a PCR a QuantStudio® 5 a Nthawi Yeniyeni Machitidwe a PCR a SLAN-96P a Nthawi Yeniyeni Dongosolo la LightCycler®480 Real-Time PCR Dongosolo Lozindikira la LineGene 9600 Plus Real-Time PCR MA-6000 Real-Time Quantitative Thermal Cycler Dongosolo la PCR la BioRad CFX96 Real-Time BioRad CFX Opus 96 Real-Time PCR System |
Kayendedwe ka ntchito
Ma reagents amafunika koma sanaperekedwe
Macro & Micro-Test Sample Release Reagent (HWTS-3005-8), Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017) (yomwe ingagwiritsidwe ntchito ndi Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-EQ011)) yochokera ku Jiangsu Macro & Micro-Test Med-Tech Co., Ltd., Normal saline, njira yosungira mkodzo.
Zinthu zogwiritsidwa ntchito zimafunika koma siziperekedwa
1.5mL ya chubu cha DNase/RNase chopanda ma centrifuge, DNase/RNase-free Tips, anhydrous ethanol, pipette, desk centrifuge, bench mixer