Mycoplasma Genitalium (Mg) Nucleic Acid Detection Kit

Kufotokozera Kwachidule:

Bokosi ili limagwiritsidwa ntchito pozindikira Mycoplasma genitalium (Mg) nucleic acid m'magazi a amuna ndi akazi.


Tsatanetsatane wa Zamalonda

Ma tag a Zamalonda

Dzina la chinthu

Mycoplasma Genitalium (Mg) Nucleic Acid Detection Kit

Epidemiology

Matenda opatsirana pogonana (STD) akadali chimodzi mwa zinthu zomwe zimawopseza chitetezo cha anthu padziko lonse lapansi, zomwe zingayambitse kusabereka, kubereka mwana asanakwane nthawi, kupangika kwa chotupa, ndi mavuto ena akuluakulu [1-4]. Pali mitundu yambiri ya matenda opatsirana pogonana, kuphatikizapo mabakiteriya, mavairasi, chlamydia, mycoplasma, ndi spirochetes. Mitundu yodziwika bwino ndi Neisseria gonorrhoeae, Chlamydia trachomatis, Ureaplasma urealyticum, Herpes simplex virus type 1, Herpes simplex virus type 2, Mycoplasma hominis, Mycoplasma genitalium ndi zina zotero.

Njira

FAM Mg
ROX

Kulamulira Kwamkati

Magawo aukadaulo

Malo Osungirako

-18℃

Nthawi yokhalitsa Miyezi 12
Mtundu wa Chitsanzo ukutulutsa kwa m'chiwuno,kutulutsa madzi m'chiberekero
Tt ≤38
CV ≤5.0%
LoD Makopi 500/μL
Kufotokozera Mwapadera Palibe njira yolumikizirana ndi matenda ena opatsirana pogonana, monga Chlamydia trachomatis, Ureaplasma urealyticum, Neisseria gonorrhoeae, Mycoplasma hominis, Herpes simplex virus type 1, ndi Herpes simplex virus type 2.
Zida Zogwiritsidwa Ntchito Machitidwe a Biosystems 7500 a Real-Time PCRQuantStudio®Machitidwe 5 a PCR a Nthawi Yeniyeni

Machitidwe a PCR a SLAN-96P a Nthawi Yeniyeni

Woyendetsa Sitima Yopepuka®Dongosolo la PCR la 480 Real-Time

Dongosolo Lozindikira la LineGene 9600 Plus Real-Time PCR

MA-6000 Real-Time Quantitative Thermal Cycler

Dongosolo la PCR la BioRad CFX96 Real-Time

BioRad CFX Opus 96 Real-Time PCR System

Kayendedwe ka ntchito

Mycoplasma Genitalium (Mg) Nucleic Acid Detection Kit

Ma reagents amafunika koma sanaperekedwe

Saline wamba, Macro & Micro-Test Sample Release Reagent (HWTS-3005-8), Macro & Micro-Test General DNA/RNA Kit (HWTS-3017) ndi Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B), Nucleic Acid Extraction kapena Purification Reagent (YDP302) yochokera ku Tiangen Biotech (Beijing) Co., Ltd.

Zinthu zogwiritsidwa ntchito zimafunika koma siziperekedwa

1.5 mL ya machubu a DNase/RNase opanda ma centrifuge, matipi a DNase/RNase opanda ma DNase, machubu 8 a PCR, pipette, desktop centrifuge, chosakanizira cha desktop oscillation.


  • Yapitayi:
  • Ena:

  • Lembani uthenga wanu apa ndipo mutitumizireni