SARS-CoV-2 Spike RBD Antibody

Kufotokozera Kwachidule:

Enzyme-Linked Immunosorbent Assay pozindikira SARS-CoV-2 Spike RBD Antibody idapangidwa kuti izindikire valence ya Antibody ya SARS-CoV-2 Spike RBD Antigen mu seramu / plasma kuchokera kwa anthu omwe adalandira katemera wa SARS-CoV-2.


Tsatanetsatane wa Zamalonda

Zolemba Zamalonda

Dzina la malonda

HWTS-RT055A-Enzyme-Linked Immunosorbent Assay pozindikira SARS-CoV-2 Spike RBD Antibody

Satifiketi

CE

Epidemiology

Matenda a Coronavirus 2019 (COVID-19) ndi chibayo choyambitsidwa ndi kachilombo katsopano kamene kamatchedwa kuti acute acute kupuma kwa coronavirus 2 (SARS-CoV-2).SARS-CoV-2 inali vuto la kachilombo ka beta-CoV lopangidwa ndi tinthu tating'onoting'ono tozungulira kapena tozungulira tokhala ndi mainchesi pafupifupi 60nm-140nm.COVID-19 ndi matenda opatsirana kwambiri opatsirana, ndipo anthu nthawi zambiri amatengeka.Pakali pano gwero la matenda a COVID-19 ali ndi kachilombo ka COVID-19 komanso onyamula asymptomatic a SARS-CoV-2.Kuchuluka kwa anthu obwera ndi katemera wa SARS-CoV-2 kumatha kupanga ma spike RBD antibody kapena S antibody a SARS-CoV-2 odziwika mu seramu ndi plasma, zomwe zitha kukhala chizindikiro chowunika momwe katemera wa SARS-CoV-2 amathandizira.

Magawo aukadaulo

Kusungirako

2-8 ℃

Alumali moyo

12 miyezi

Mtundu wa Chitsanzo

seramu yaumunthu, madzi a m'magazi, zitsanzo zokhala ndi anticoagulant ya EDTA, heparin sodium ndi sodium citrate

CV

≤15.0%

LoD

Zidazi zidatsimikiziridwa ndi zolemba za opanga LOD ndi mgwirizano wa 100%.

Mwatsatanetsatane

Zinthu zosokoneza zomwe zili m'chitsanzo sizimakhudza magwiridwe antchito amtundu wa SARS-CoV-2 spike RBD antibody.Zomwe zinayesedwa zosokoneza zinaphatikizapo hemoglobin (500mg/dL), bilirubin (20mg/dL), triglyceride (1500 mg/dL), heterophil antibody (150U/mL), rheumatoid factor (100U/mL), 10% (v/v) magazi a munthu, phenylephrine (2mg/mL), oxymetazoline (2mg/mL), sodium kolorayidi (preservative kuphatikizapo) (20mg/mL), beclomethasone (20mg/mL), dexamethasone (20mg/mL), flunisolide (20μg/mL), Triamcinolone (2mg/mL), budesonide (2mg/mL), Mometasone (2mg/mL), fluticasone (2mg/mL), Histamine Dihydrochloride (5mg/mL), ainterferon (800IU/mL), zanamivir (20mg/mL), ribavirin (10mg/mL), oseltamivir (60ng/mL), Peramivir (1mg/mL) lopinavir (500mg/mL), ritonavir (1mg/mL), mupirocin (20mg/mL), azithromycin (1mg/mL), cefprozil ( 40μg/mL) ndi meropenem (200mg/mL).Levofloxacin (10μg/mL), tobramycin (0.6mg/mL), EDTA (3mg/mL), Heparin Sodium (25U/mL), ndi Sodium Citrate (12mg/mL)

Zida Zomwe Zingagwiritsidwe Ntchito:

Wowerenga wa Universal microplate pa wavelength 450nm/630nm.

Kuyenda Ntchito

Njira 1.

Analimbikitsa m'zigawo reagent: Macro & Micro-Test Viral DNA/RNA Kit(HWTS-3001, HWTS-3004-32, HWTS-3004-48) ndi Macro & Micro-Test Automatic Nucleic Acid Extractor(HWTS-3006).

Njira 2.

Zomwe zimalangizidwa m'zigawo: Nucleic Acid Extraction kapena Purification Reagent(YDP302) yolembedwa ndi Tiangen Biotech(Beijing) Co.,Ltd.


  • Zam'mbuyo:
  • Ena: