HPV16 ndi HPV18

Kufotokozera Kwachidule:

Kiti iyi ndi ya intenadapangidwa kuti apezeke mu vitro qualitative detection of specific nucleic acid fragments of human papillomavirus (HPV) 16 ndi HPV18 m'maselo achikazi otulutsidwa m'chiberekero.


Tsatanetsatane wa Zamalonda

Ma tag a Zamalonda

Dzina la chinthu

HWTS-CC001-Kiti Yodziwira HPV16 ndi HPV18 Nucleic Acid (Fluorescence PCR)

Epidemiology

Khansa ya pachibelekero ndi imodzi mwa zotupa zoopsa kwambiri m'njira yoberekera ya akazi. Zawonetsedwa kuti matenda a HPV osatha komanso matenda ambiri ndi chimodzi mwa zifukwa zazikulu za khansa ya pachibelekero. Pakadali pano palibe njira zovomerezeka zochiritsira khansa ya pachibelekero yomwe imayambitsidwa ndi HPV. Chifukwa chake, kuzindikira msanga ndi kupewa matenda a pachibelekero omwe amayambitsidwa ndi HPV ndiye njira zopewera khansa ya pachibelekero. Kukhazikitsa mayeso osavuta, enieni komanso ofulumira ozindikira matenda ndikofunikira kwambiri pakupeza matenda a pachibelekero.

Njira

Njira Mtundu
FAM HPV18
VIC/HEX HPV16
CY5

Kulamulira Kwamkati

Magawo aukadaulo

Malo Osungirako

≤-18℃

Nthawi yokhalitsa Miyezi 12
Mtundu wa Chitsanzo selo lochotsedwa m'chiberekero
Ct ≤28
CV ≤10.0%
LoD Makope 500/mL
Kufotokozera Mwapadera Mukagwiritsa ntchito chidachi kuyesa zitsanzo zosakhudzana ndi zomwe zingagwiritsidwe ntchito, zotsatira zake zonse zimakhala zoipa, kuphatikizapo Ureaplasma urealyticum, Chlamydia trachomatis, Candida albicans, Neisseria gonorrhoeae, Trichomonas vaginalis, Mildew, Gardnerella ndi mitundu ina ya HPV yomwe siili mu chidachi.
Zida Zogwiritsidwa Ntchito SLAN®-96P Real-Time PCR SystemsMachitidwe a Biosystems 7500 a Real-Time PCR

QuantStudio®Machitidwe 5 a PCR a Nthawi Yeniyeni

Woyendetsa Sitima Yopepuka®Dongosolo la PCR la 480 Real-Time

LineGene 9600 Plus Real-Time PCR Detection System (FQD-96A, ukadaulo wa Hangzhou Bioer)

MA-6000 Real-Time Quantitative Thermal Cycler.

Kuyenda kwa Ntchito

Njira 1.

Macro & Micro-Test Sample Release Reagent (HWTS-3005-8), iyenera kuchotsedwa motsatira malangizo.

Njira yachiwiri.

Macro & Micro-Test General DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) ndi Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006B, HWTS-3006C), iyenera kuchotsedwa motsatira malangizo. Voliyumu ya chitsanzo chochotsedwa ndi 200μL, ndipo voliyumu yovomerezeka ya elution ndi 80µL.

Njira 3.

QIAamp DNA Mini Kit (51304) yopangidwa ndi QIAGEN kapena TIANamp Virus DNA/RNA Kit (YDP315) yopangidwa ndi Tiangen Biotech (Beijing) Co., Ltd., iyenera kuchotsedwa motsatira malangizo. Kuchuluka kwa chitsanzo chochotsedwa ndi 200μL, ndipo kuchuluka koyenera kwa elution ndi 80µL.


  • Yapitayi:
  • Ena:

  • Lembani uthenga wanu apa ndipo mutitumizireni