Hepatitis B Virus RNA
Dzina la malonda
HWTS-HP007 Hepatitis B Virus RNA Nucleic Acid Detection Kit (Fluorescence PCR)
Epidemiology
Qkudziwika kosavomerezeka kwa milingo ya HBV-RNA mu seramu kumatha kuwunika bwino kuchuluka kwa HBV cccDNA mu hepatocytes, ndipo nthawi yomweyo kupewa kuwononga kwambiri odwala.Ndikofunikira kwambiri pakuzindikiritsa kothandizira kwa kachilombo ka hepatitis B (HBV) komanso kuwunika kogwira mtima komanso kuneneratu za kusiya mankhwala kwa NAs antiviral therapy mwa odwala CHB.
Channel
FAM | HBV-RNA |
Mtengo ROX | Ulamuliro Wamkati |
Magawo aukadaulo
Kusungirako | ≤-18 ℃ |
Alumali moyo | 9 miyezi |
Mtundu wa Chitsanzo | seramu |
Tt | ≤42 |
CV | ≤5.0% |
LoD | 100 makopi / ml |
Mwatsatanetsatane | Zotsatira zosokoneza zikuwonetsa kuti palibe zotsatira pakutsimikiza kwa HBV RNA pamene kuchuluka kwa bilirubin mu seramu sikuposa 168.2μmol/mL, kuchuluka kwa hemoglobini komwe kumapangidwa ndi hemolysis sikupitilira 130g/L, kuchuluka kwa lipids m'magazi sikuposa 65mmol/mL;palibe zotsatira pa kutsimikiza kwa HBV RNA pamene chiwerengero chonse cha IgG mu seramu sichiposa 5mg/mL.Zotsatira za mayeso a cross-reactivity zikuwonetsa kuti palibe kusinthana pakati pa zida izi ndi ma virus ena kapena mabakiteriya omwe amapezeka ndi nucleic acid m'magazi (kachilombo ka hepatitis C, human cytomegalovirus, epstein-barr virus, human immunodeficiency virus, hepatitis A virus, syphilis. , mtundu wa 6 wa herpes virus, herpes simplex virus type 2, virus ya fuluwenza A, propionibacterium acnes, staphylococcus aureus, candida albicans) ndi ma genome a anthu;odwala atatenga lamivudine, telbivudine, adefovir dipivoxil ndi entecavir, pamene mavairasi a hepatitis B m'thupi ali pamwamba pa LoD yochepa ya kit, chidacho chikhoza kudziwika bwino. |
Zida Zogwiritsira Ntchito | Applied Biosystems 7500 Real-Time PCR SystemApplied Biosystems 7500 Fast Real-Time PCR Systems SLAN-96P Real-Time PCR Systems (Hongshi Medical Technology Co., Ltd.) |
Kuyenda Ntchito
Njira 1.
Viral DNA/RNA Isolation Kit (NA007-2) yolembedwa ndi GenMag Biotechnology Co., Ltd. Njira zenizeni zochotsera chonde tsatirani mosamalitsa buku la malangizo.
Macro & Micro-Test General DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (yomwe ingagwiritsidwe ntchito ndi Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) ndi Jiangsu Macro & yaying'ono-Test Med-Tech Co., Ltd. The m'zigawo ziyenera kuchitidwa molingana ndi malangizo buku, yotengedwa chitsanzo voliyumu ndi 200μL, ndi analimbikitsa elution voliyumu ndi 80μl pa.